New Energy Co., Ltd., Guangdong Bao Wei not
only provide customers with professional stent design for the total package
provides turnkey photovoltaic power plant construction services, with
professional knowledge and rich experience, Paul Wei inverter for supporting
the selection of components and also can give constructive comments.
Since crystalline silicon cell module fill
factor is high, the peak point of the inverter is easy to find, but amorphous
silicon thin film battery pack is relatively low fill factor, IV curve is
gentle, the grid connected inverter need to set the step voltage tracking MPPT to find the
peak point.
Meanwhile amorphous silicon thin film
batteries need negative ground, in order to discharge static electricity and
prevent common mode voltage to ground exceeds the system voltage and the
inhibition photovoltaic array panels on the distributed capacitance of the
inverter control circuit common mode interference. So you must use an internal
or external transformer isolation (including step-up transformer) for grid
inverters, grounding lines need to add DC leakage protection device to protect
the personal safety.
Combining the above reasons, on negative
ground can use the following improvements: negative ground is not grounding
lightning protection components, but mainly to prevent static electricity, so
you can use indirect grounding method, using a large value resistors indirectly
grounded to avoid causing direct ground with no transformer-isolated modified sine wave inverter incompatibility problems.
Since the grounding resistor through the
actual current is very small, will not cause the inverter without
transformer-isolated DC leakage alarm, while the DC grounding line leakage
protection settings can play a small role in protecting the safety of
personnel. The only downside is indirectly grounded in the inhibition of cell
panel distributed capacitance of the inverter reduces common mode interference
aspect, and this problem can be reduced distributed capacitance (eg with no
border component) and the inverter internal circuitry to improve noise immunity
resolved, and now most of the inverter can be fit.